StaffAttract
  • Login
  • Create Account
  • Products
    • Private Ad Placement
    • Reports Management
    • Publisher Monetization
    • Search Jobs
  • About Us
  • Contact Us
  • Unsubscribe

Login

Forgot Password?

Create Account

Job title, industry, keywords, etc.
City, State or Postcode

NETA Level II / Substation Testing Technician - 480V ...

Stealth Startup - Richardson, TX

Apply Now

Job Description

This is a senior-level High Voltage Technician role in an industrial setting, responsible for supporting and maintaining electrical systems from 480V up to 138kV. The work includes maintaining and troubleshooting transformers, switchgear, and breakers, performing preventive maintenance, running electrical tests, reviewing prints, updating procedures, and making sure all work is done safely using proper lockout/tagout practices.You'll also be involved in commissioning new equipment, working with utility providers, and keeping power systems stable and reliable. This role requires NETA Level II certification or equivalent high-voltage testing experience, along with strong leadership, and the ability to work well with a team.Military Veterans "” Your recent HV Experience Counts!Army 12P "” Prime Power Production Specialist (utility-grade HV systems, substations)Navy EM / EMN "” Electrician's Mate (HV power distribution, switchgear, transformers)Air Force 3E0X1 "” Electrical Systems Specialist (base electrical distribution, HV switching)Army 91C "” Utilities Equipment Repairer (HV distribution at fixed installations)Marines 1161 "” Utilities Chief (supervision of HV utilities operations)AS A HIGH VOLTAGE TECHNICIAN, YOU CAN EXPECT TO HAVE THESE RESPONSIBILITIES:Perform preventive maintenance (PM) on all electrical equipment, including 138kV air switches, 138kV SF6 gas circuit breaker, 138kV-13.8kV transformers, 13.8kV-4,160V transformers, 13.8kV-480V transformers, 15kV switchgear, 15kV switch line-ups, 15kV vacuum bottle circuit breakers, 480V switchgear, and 480V rackable circuit breakerCreate maintenance schedules, work documents, JHA, work permits, etc., as necessaryTroubleshoot and repair electrical equipment, including testing and replacing components as neededUtilize LOTO (lockout/tagout) procedures to isolate hazards during the switching process, ensuring a safe working environment for the teamWork closely with cross-functional teams, including engineering, logistics, and factory operations, to ensure that electrical distribution system maintenance aligns with business goals and objectivesDevelop and approve procedures for preventive maintenance and lockout/tagoutThis includes reviewing one-line drawings and schematics in this processOversee contractor performance from time to time in all of the above categoriesThis includes inspection reports of as-found and as-left conditionsPerform offline electrical testing on high voltage systemEvaluate offline electrical testing results and provide recommendations for servicing or repairsPerform factory acceptance, site commissioning, and site acceptance of high voltage equipment rated 480V-138kVMaintain equipment end-of-life documentation and provide recommendations to update assets for maintainabilityEvaluate system performance and provide direction on system manipulation to maintain power quality, diversity, and reliability standardsInterface with the electric utility companies to ensure site reliability, growth, and interdependent work is coordinated effectivelyManage, update, and modify system standard operating procedures (SOPs) to keep up to date with changing industry standardsManage, update, and modify drawings, diagrams, and schematics as requiredTO BE SUCCESSFUL, YOU'LL NEED EXPERIENCE SUCH AS:All individuals must have a commitment to the team above selfOvertime and call-ins may be requiredHolds a NETA level 2 certification -OR- have taken the following 3 courses in the last 3-5 years, and have at least 2 years of experience in industrial high voltage testing -OR- equivalent military training/experienceIndustrial Electrical Safety - typically 4 days, 2.8 CEUs | classroom lectureSubstation Maintenance I - typically 4.5 days, 3.2 CEUs | classroom lecture & hands-on trainingSubstation Maintenance II - typically 4.5 days, 3.2 CEUs | classroom lecture & hands-on trainingADDITIONAL INFORMATION ABOUT THIS ROLE:Candidates must be authorized to work in the United States

Created: 2026-05-09

➤
Footer Logo
Privacy Policy | Terms & Conditions | Contact Us | About Us
Designed, Developed and Maintained by: NextGen TechEdge Solutions Pvt. Ltd.